Wright Austin TS Gas Liquid Separators
316SS separators for
up to 60% by weight of the units flow capacity

304/316 SIZE CONNECTION PART NUMBER
316SS 1" FNPT, 500 PSI @ 300°F 1TSS6
SWE, 500 PSI @ 300°F 1TSWS
150# RF ANSI FLANGED, 150 PSI @ 450°F 1TS150S6
300# RF ANSI FLANGED, 500 PSI @ 650°F 1TS500S6
316SS 1¼" FNPT, 500 PSI @ 300°F 1.25TSS6
SWE, 500 PSI @ 300°F 1.25TSWS6
150# RF ANSI FLANGED, 150 PSI @ 450°F 1.25TS150S6
300# RF ANSI FLANGED, 500 PSI @ 650°F 1.25TS500S6
316SS 1½" FNPT, 500 PSI @ 300°F 1.5TSS6
SWE, 500 PSI @ 300°F 1.5TSWS6
150# RF ANSI FLANGED, 150 PSI @ 450°F 1.5TS150S6
300# RF ANSI FLANGED, 500 PSI @ 650°F 1.5TS500S6
316SS 2" FNPT, 500 PSI @ 300°F 2TSCS6
SWE, 500 PSI @ 300°F 2TSWS6
150# RF ANSI FLANGED, 150 PSI @ 450°F 2TS150S6
300# RF ANSI FLANGED, 500 PSI @ 650°F 2TS500S6
304SS 2½" 150# RF ANSI FLANGED, 150 PSI @ 450°F 2.5TS150S
300# RF ANSI FLANGED, 500 PSI @ 650°F 2.5TS500S
304SS 3" 150# RF ANSI FLANGED, 150 PSI @ 450°F 3TS150S
300# RF ANSI FLANGED, 500 PSI @ 650°F 3TS500S
304SS 4" 150# RF ANSI FLANGED, 150 PSI @ 450°F 4TS150S
300# RF ANSI FLANGED, 500 PSI @ 650°F 4TS500S
304SS 5" 150# RF ANSI FLANGED, 150 PSI @ 450°F 5TS150S
300# RF ANSI FLANGED, 500 PSI @ 650°F 5TS500S
304SS 6" 150# RF ANSI FLANGED, 150 PSI @ 450°F 6TS150S
300# RF ANSI FLANGED, 500 PSI @ 650°F 6TS500S
304SS 8" 150# RF ANSI FLANGED, 150 PSI @ 450°F 8TS150S
300# RF ANSI FLANGED, 500 PSI @ 650°F 8TS500S
304SS 10" 150# RF ANSI FLANGED, 150 PSI @ 450°F 10TS150S
300# RF ANSI FLANGED, 500 PSI @ 650°F 10TS500S
304SS 12" 150# RF ANSI FLANGED, 150 PSI @ 450°F 12TS150S
300# RF ANSI FLANGED, 500 PSI @ 650°F 12TS500S
Performance Overview

TS gas/liquid separators are designed to remove entrained liquid and solids from air, steam or industrial process gases.  This specific (elongated body) design is effective for applications where the entrained liquid flow rate is up to 60% by weight of the units flow capacity.

When properly sized, this separator will remove up to 99% of all liquid and solids greater than 10 microns in size from an air, gas or steam flow.  The removal is accomplished by a design that causes the air/gas/steam to enter a controlled centrifugal flow.  This results in forcing the entrained material to the outer wall and the VCP prevents re-entrainment.

TS separators are constructed to ASME code for unfired vessels, Section VIII, Division 1 but NOT stamped.  An ASME stamp and CRN registration is available for sizes 2 inches and larger.


Options:
• To upgrade from 304 SS to 316SS contact our office for pricing
• ½" thermometer connection
• larger drain size
• Code stamp and CRN available

Lead Time:
Availability of custom fabricated TS air liquid separators is typically 8-12 weeks. If the lead time is critical, please contact our office and obtain a lead-time estimate based upon the current manufacturing backlog.

Outline Drawings:

Click on part number to view outline drawing

Use this carbon steel drawing for approximate dimensions when individual drawings aren't available (approval drawings are generated prior to manufacturing).

Engineering Information:
Air Sizing Chart
Steam Sizing Chart

Formulas and Constants

If you need assistance with proper selection and for pipeline sizes > 12" please fill-out our inquiry form.